Engineering resource

Cable Ladder & Tray Selector

Enter how much your cables weigh per metre and how far apart the supports are. You’ll see every tested Array Metal ladder, tray and wire-mesh model that can safely carry them. The full published load tables follow below.

  • IEC 61537:2006
  • NEMA VE1-2009
  • Tested by SIRIM

Load selector

kg/m
m
Standard
Show

14 models carry 0 kg/m at 3 m spacing

  1. AML · Cable Ladder

    AML100

    156 kg/m IEC 61537

    0% of SWL used
    NEMA VE1
    192 kg/m
    Support spacing
    3 m
    Fill depth
    75 mm
  2. AML · Cable Ladder

    AML125

    456 kg/m IEC 61537

    0% of SWL used
    NEMA VE1
    480 kg/m
    Support spacing
    3 m
    Fill depth
    100 mm
  3. AML · Cable Ladder

    AML150

    468 kg/m NEMA VE1

    0% of SWL used
    IEC 61537
    504 kg/m
    Support spacing
    3 m
    Fill depth
    125 mm
  4. APO · Cable Ladder

    APO100

    192 kg/m NEMA VE1

    0% of SWL used
    IEC 61537
    228 kg/m
    Support spacing
    3 m
    Fill depth
    75 mm
  5. APO · Cable Ladder

    APO125

    408 kg/m IEC 61537

    0% of SWL used
    NEMA VE1
    416 kg/m
    Support spacing
    3 m
    Fill depth
    100 mm
  6. APO · Cable Ladder

    APO150

    452 kg/m IEC 61537

    0% of SWL used
    NEMA VE1
    540 kg/m
    Support spacing
    3 m
    Fill depth
    125 mm
  7. ACD · Cable Ladder

    ACD100

    239 kg/m IEC 61537

    0% of SWL used
    Support spacing
    3 m
    Fill depth
    75 mm
  8. ACD · Cable Ladder

    ACD125

    560 kg/m IEC 61537

    0% of SWL used
    Support spacing
    3 m
    Fill depth
    100 mm
  9. ACD · Cable Ladder

    ACD150

    579 kg/m IEC 61537

    0% of SWL used
    Support spacing
    3 m
    Fill depth
    125 mm
  10. ART · Cable Tray

    ART50

    98 kg/m IEC 61537

    0% of SWL used
    NEMA VE1
    121 kg/m
    Support spacing
    3 m
    Fill depth
    50 mm
  11. AMT · Cable Tray

    AMT100

    179 kg/m NEMA VE1

    0% of SWL used
    IEC 61537
    269 kg/m
    Support spacing
    3 m
    Fill depth
    100 mm
  12. AWT · Wire Mesh Tray

    AWT50

    22 kg/m NEMA VE1

    0% of SWL used
    Support spacing
    3 m
    Fill depth
    50 mm
  13. AWT · Wire Mesh Tray

    AWT100

    24 kg/m NEMA VE1

    0% of SWL used
    Support spacing
    3 m
    Fill depth
    100 mm
  14. AWT · Wire Mesh Tray

    AWT100

    62 kg/m NEMA VE1

    0% of SWL used
    Support spacing
    3 m
    Fill depth
    100 mm

SWL = safe working load, safety factor included. Uniform load, HDG steel. Ladder is tested at 6 m and tray at 3 m; shorter spans are interpolated. No rating yet for ALT, ASL or other series — ask our engineers.

Cable Ladder

AML Series

Hot-Dip Galvanized (HDG) · Safety factor ×1.5

NEMA VE1-2009
ModelFill depthThickness3 mSWL kg/m4.5 mSWL kg/m6 mSWL kg/mNEMA class
AML10075 mm1.5 / 2 mm192854820AA
AML125100 mm1.5 / 2 mm48021312020B
AML150125 mm1.5 / 2 mm46820811720B

Rating basis. SWL = Destructive load ÷ 1.5 (NEMA VE1-2009). Available lengths: 3 m and 6 m. Deflection limit: L/100 at SWL. 3 m and 4.5 m figures are interpolated from the 6 m test.

Cable Ladder

AML Series

Hot-Dip Galvanized (HDG) · Safety factor ×1.7

IEC 61537:2006
ModelFill depthThickness3 mSWL kg/m4.5 mSWL kg/m6 mSWL kg/m
AML10075 mm1.5 / 2 mm1566939
AML125100 mm1.5 / 2 mm456203114
AML150125 mm1.5 / 2 mm504224126

Rating basis. SWL = Breaking load ÷ 1.7 (IEC 61537:2006, Test Type 2). Available lengths: 3 m and 6 m. 3 m and 4.5 m figures are interpolated from the 6 m test.

Cable Ladder

APO Series

Hot-Dip Galvanized (HDG) · Safety factor ×1.5

SIRIM / NEMA VE1-2009
ModelFill depthThickness3 mSWL kg/m4.5 mSWL kg/m6 mSWL kg/mNEMA class
APO10075 mm1.5 / 2 mm192854820AA
APO125100 mm1.5 / 2 mm41618510420A
APO150125 mm1.5 / 2 mm54024013520B

Rating basis. SWL = Destructive load ÷ 1.5 (NEMA VE1-2009). Test certificate reference: SIRIM-NEMA VE1-2009. Available lengths: 3 m and 6 m. 3 m and 4.5 m figures are interpolated from the 6 m test.

Cable Ladder

APO Series

Hot-Dip Galvanized (HDG) · Safety factor ×1.7

IEC 61537:2006
ModelFill depthThickness3 mSWL kg/m4.5 mSWL kg/m6 mSWL kg/m
APO10075 mm1.5 / 2 mm22810157
APO125100 mm1.5 / 2 mm408181102
APO150125 mm1.5 / 2 mm452201113

Rating basis. SWL = Breaking load ÷ 1.7 (IEC 61537:2006, Test Type 2). Available lengths: 3 m and 6 m. 3 m and 4.5 m figures are interpolated from the 6 m test.

Cable Ladder

ACD Series

Hot-Dip Galvanized (HDG) · Safety factor ×1.7

IEC 61537:2006
ModelFill depthThickness3 mSWL kg/m4.5 mSWL kg/m6 mSWL kg/m
ACD10075 mm1.5 mm (tested)23910660
ACD125100 mm1.5 / 2 mm560249140
ACD150125 mm1.5 / 2 mm579257145

Rating basis. SWL = Breaking load ÷ 1.7 (IEC 61537:2006). Breaking load confirmed ≥ 1.7 × SWL by test. Certificate ref: 2018MA0594-ACD-IEC61537. Available lengths: 3 m and 6 m. Full test certificate available on request. 3 m and 4.5 m figures are interpolated from the 6 m test.

Cable Tray

ART / AMT Series

Hot-Dip Galvanized (HDG) · Safety factor ×1.5

NEMA VE1-2009
ModelFill depthThickness1.5 mSWL kg/m2 mSWL kg/m3 mSWL kg/mNEMA class
ART5050 mm1.5 / 2 mm48427212120AA
AMT100100 mm1.5 / 2 mm71640317920B

Rating basis. SWL = Destructive load ÷ 1.5 (NEMA VE1-2009). Available lengths: 3 m and 6 m. Deflection limit: L/100 at SWL. 1.5 m and 2 m figures are interpolated from the 3 m test.

Cable Tray

ART / AMT Series

Hot-Dip Galvanized (HDG) · Safety factor ×1.7

IEC 61537:2006
ModelFill depthThickness1.5 mSWL kg/m2 mSWL kg/m3 mSWL kg/m
ART5050 mm1.5 / 2 mm39222198
AMT100100 mm1.5 / 2 mm1076605269

Rating basis. SWL = Breaking load ÷ 1.7 (IEC 61537:2006, Test Type 2). Available lengths: 3 m and 6 m. 1.5 m and 2 m figures are interpolated from the 3 m test.

Wire Mesh Tray

AWT Series

Hot-Dip Galvanized (HDG) · Safety factor ×1.5

NEMA VE1
ModelFill depthThickness1.5 mSWL kg/m2 mSWL kg/m3 mSWL kg/mNEMA class
AWT5050 mm4.5 mm wire8850225A
AWT100100 mm4.5 mm wire9654248AA
AWT100100 mm5.9 mm wire2481406210AA

Rating basis. SWL = Destructive load ÷ 1.5 (NEMA VE1). AWT100 has separate ratings for 4.5 mm and 5.9 mm wire diameters.

Methodology

Test conditions and safety factors

Every figure on this page is a safe working load with the standard’s safety factor already applied. Fill depth is the usable cable depth inside the side rail.

NEMA VE1-2009

APO · AML · ART · AMT · AWT series

Test type
Single-span, uniformly distributed load
Ladder spans
Tested at 6 m; 3 m and 4.5 m interpolated
Tray spans
Tested at 3 m; 1.5 m and 2 m interpolated
Safety factor
×1.5
SWL definition
Destructive load ÷ 1.5
Deflection limit
L/100 at SWL
Load classification
5A, 8AA, 10AA, 10A, 20AA, 20A, 20B (increasing capacity)
Test body
SIRIM (Malaysia)

IEC 61537:2006

ACD · AML · APO · ART · AMT series

Test type
Single-span, uniformly distributed load
Ladder spans
Tested at 6 m; 3 m and 4.5 m interpolated
Tray spans
Tested at 3 m; 1.5 m and 2 m interpolated
Safety factor
×1.7
SWL definition
Breaking load ÷ 1.7
Deflection limit
L/100 at SWL
Breaking load
Confirmed ≥ 1.7 × SWL by test
Certificate ref
2018MA0594-ACD-IEC61537

NEMA classification per NEMA VE1-2009: 20AA < 20A < 20B (increasing capacity).

Need the test certificates?

Test reports and vendor prequalification documents are on the certifications page. For a load case outside these tables, send it to our engineering team.

Chat on WhatsApp